Magnetic measurements of undulator was complete by January 2005

Close up of Hall probe in gap
  Hall probe scanner by undulator
  Considering shimming actuators
The magnetic field in the assembled undulator was measured with a scanning Hall probe along several beam-parallel tracks. Mechanical shims were added to gap actuators to achieve the design field uniformity.

Use mouse over to view full scale images.