Shimming and measurements of undulator magnet structure was completed by Dec 2005

Close up of pulsed wire probe
  First wire probe measurements
  Shimming of full assembly
Beam trajectory measurents with a pulsed wire probe were used to evaluate and test magnetic shims that make the average filed uniform along each magnet array.

Use mouse over to view images.

  Initial trajectory
  Trajectory after shimming